Table 20. C1001F00 to C1645300 checkpoints (continued)
v If the system hangs on a progress code, follow the suggested actions in the order in which they are listed in
the Action column until the problem is solved. If an action solves the problem, you can stop performing the
remaining actions.
v See Chapter 3, "Parts listing, type 7891," on page 225 to determine which components are CRUs and which
components are FRUs.
Progress code
C1009xC8
C1009xCC
C1009xD0
C1009xD4
C103A1xx
C103A2xx
C103A3xx
C103A400
C103A401
C116C2xx
Description
Start PRD step in progress
Message passing waiting period has
begun
Message passing waiting period has
begun
Starting elastic interface calibration
Hypervisor code modules are being
transferred to system storage
Hypervisor data areas are being built in
system storage
Hypervisor data structures are being
transferred to system storage
Special purpose registers are loaded and
instructions are started on the system
processors
Instructions have been started on the
system processors
System power interface is listening for
power fault events from SPCN. The last
byte (xx) will increment up from 00 to
1F every second while it waits.
Action
1. Go to "Checkout procedure" on page 176.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 264.
1. Go to "Checkout procedure" on page 176.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 264.
1. Go to "Checkout procedure" on page 176.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 264.
1. Go to "Checkout procedure" on page 176.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 264.
1. Go to "Checkout procedure" on page 176.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 264.
1. Go to "Checkout procedure" on page 176.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 264.
1. Go to "Checkout procedure" on page 176.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 264.
1. Go to "Checkout procedure" on page 176.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 264.
1. Go to "Checkout procedure" on page 176.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 264.
1. Go to "Checkout procedure" on page 176.
2. Replace the system-board, as described in
"Replacing the FRU system-board and
chassis assembly" on page 264.