IBM PS703 Service Manual page 72

7891-73x;7891-74x
Hide thumbs Also See for PS703:
Table of Contents

Advertisement

Table 17. B7xxyyy Licensed internal code SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, type 7891," on page 225 to determine which components are CRUs and which
components are FRUs.
B700 xxxx Error Codes
6A30
BA01
BAD1
BAD2
F103
F104
F105
F106
F107
F108
F10A
F10B
60
Power Systems: Problem Determination and Service Guide for the IBM PS703 (7891-73X) and PS704 (7891-74X)
Description
A PCI-E bus internal connection
initialized to a lower bus configuration
than expected. The bus is operational,
but operating at a bandwidth below its
rated capacity. This might lead to
degraded I/O throughput.
During analysis of a previous
serviceable error, a request to activate a
FRU fault indicator was not successful.
The platform firmware detected an
error.
System firmware detected an error.
System firmware failure
Operating system error. System
firmware terminated a partition.
System firmware detected an internal
error
System firmware detected an error
System firmware detected an error.
A firmware error caused the system to
terminate.
System firmware detected an error
A processor resource has been disabled
due to hardware problems
Action
Replace the system-board and chassis
assembly, as described in "Replacing the FRU
system-board and chassis assembly" on page
264.
Replace the system-board and chassis
assembly, as described in "Replacing the FRU
system-board and chassis assembly" on page
264.
Go to "Isolating firmware problems" on page
216.
1. Collect the event log information.
2. Go to "Isolating firmware problems" on
page 216.
1. Collect the event log information.
2. Collect the platform dump information.
3. Go to "Isolating firmware problems" on
page 216.
Check the management-module event log for
partition firmware error codes (especially
BA00F104); then, take the appropriate actions
for those error codes.
1. Collect the event log information.
2. Collect the platform dump information.
3. Go to "Isolating firmware problems" on
page 216.
Replace the system-board and chassis
assembly, as described in "Replacing the FRU
system-board and chassis assembly" on page
264.
1. Collect the event log information.
2. Go to "Isolating firmware problems" on
page 216.
1. Collect the event log information.
2. Go to "Isolating firmware problems" on
page 216.
Look for and correct B1xxxxxx errors.
Replace the system-board and chassis
assembly, as described in "Replacing the FRU
system-board and chassis assembly" on page
264.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ps704

Table of Contents