Table 18. BA000010 to BA400002 Partition firmware SRCs (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
v See Chapter 3, "Parts listing, type 7891," on page 225 to determine which components are CRUs and which
components are FRUs.
Error code
BA340006
BA340007
BA340008
BA340009
BA340010
BA340011
Description
An LP event communication failure
occurred reading the system initiator
capability data from the service
processor.
An internal firmware error occurred; the
open fabric manager system initiator
capability data was corrupted.
An internal firmware error occurred; the
open fabric manager system initiator
capability data version was not correct.
An internal firmware error occurred; the
open fabric manager system initiator
capability processing encountered an
unexpected error.
An internal firmware error was detected
during open fabric manager processing.
Assignment of fabric ID to the I/O
adapter failed.
Action
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
176.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 264.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
176.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 264.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
176.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 264.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
176.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 264.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
176.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 264.
1. Reboot the blade server.
2. If the problem persists:
a. Go to "Checkout procedure" on page
176.
b. Replace the system-board, as described
in "Replacing the FRU system-board
and chassis assembly" on page 264.
Chapter 2. Diagnostics
95