Table 27. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
26D2-124
26D2
26D2-126
26D2
252B
26D2-128
252B
26D2
Software
26D2-129
252B
26D2
Software
26D2-130
26D2
26D2-132
26D2
26D2-134
252B
Software
26D2-135
26D2
252B
Software
26D2-136
26D2
26D2-137
26D2
252B
26D2-138
26D2
26D2-140
199
252B
26D2
26D2-640
2D02-xxx
2631
2E00-201
2E00 221
Description and Action
A SCSI check condition error occurred.
A software error was caused by a hardware failure.
The error log analysis indicates a hardware failure.
Error log analysis indicates a SCSI bus problem.
Error log analysis indicates a problem reported by the disk drive's self-monitoring
function.
A disk drive hardware error occurred.
The adapter failed to configure.
The device failed to configure.
The certify operation failed.
Unit attention condition has occurred on the Send Diagnostic command.
Error log analysis indicates that the disk drive is operating at a higher than
recommended temperature.
Check to be sure none of the air passages in the system covers are blocked, that no
other system environmental warnings are occurring.
Error log analysis indicates poor signal quality.
Error log analysis indicates a path error.
Generic reference for USB controller/adapter - system-board and chassis assembly. Go
to "Performing the checkout procedure" on page 177.
Configuration error.
1. Check the BladeCenter management-module event log. If an error was recorded by
the system, see "POST progress codes (checkpoints)" on page 97.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board