Table 27. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
2506-8008
BAT
2506-8009
BAT
2506-8150
2506
2506-8157
2506
2506-9000
-
2506-9001
-
2506-9002
-
2506-9008
-
2506-9010
-
2506-9011
-
2506-9020
-
2506-9021
-
2506-9022
-
2506-9023
-
2506-9024
-
2506-9025
-
2506-9026
-
2506-9027
-
2506-9028
-
2506-9029
-
2506-9030
-
2506-9031
-
2506-9032
-
2506-9041
-
Description and Action
A permanent Cache Battery Pack failure occurred. Go to "Performing the checkout
procedure" on page 177.
Impending Cache Battery Pack failure. Go to "Performing the checkout procedure" on
page 177.
Controller failure. Go to "Performing the checkout procedure" on page 177.
Temporary controller failure. Go to "Performing the checkout procedure" on page 177.
Controller detected device error during configuration discovery. Go to "Performing the
checkout procedure" on page 177.
Controller detected device error during configuration discovery. Go to "Performing the
checkout procedure" on page 177.
Controller detected device error during configuration discovery. Go to "Performing the
checkout procedure" on page 177.
Controller does not support function expected for one or more disks. Go to
"Performing the checkout procedure" on page 177.
Cache data associated with attached disks cannot be found. Go to "Performing the
checkout procedure" on page 177.
Cache data belongs to disks other than those attached. Go to "Performing the checkout
procedure" on page 177.
Two or more disks are missing from a RAID-5 or RAID 6 Disk Array. Go to
"Performing the checkout procedure" on page 177.
Two or more disks are missing from a RAID-5 or RAID 6 Disk Array. Go to
"Performing the checkout procedure" on page 177.
Two or more disks are missing from a RAID-5 or RAID 6 Disk Array. Go to
"Performing the checkout procedure" on page 177.
One or more Disk Array members are not at required physical locations. Go to
"Performing the checkout procedure" on page 177.
Physical location of Disk Array members conflict with another Disk Array. Go to
"Performing the checkout procedure" on page 177.
Incompatible disk installed at degraded disk location in Disk Array. Go to "Performing
the checkout procedure" on page 177.
Previously degraded disk in Disk Array not found at required physical location. Go to
"Performing the checkout procedure" on page 177.
Disk Array is or would become degraded and parity data is out of synchronization. Go
to "Performing the checkout procedure" on page 177.
Maximum number of functional Disk Arrays has been exceeded. Go to "Performing the
checkout procedure" on page 177.
Maximum number of functional Disk Arrays disks has been exceeded. Go to
"Performing the checkout procedure" on page 177.
Disk Array is degraded due to missing/failed disk. Go to "Performing the checkout
procedure" on page 177.
Automatic reconstruction initiated for Disk Array. Go to "Performing the checkout
procedure" on page 177.
Disk Array is degraded due to missing/failed disk. Go to "Performing the checkout
procedure" on page 177.
Background Disk Array parity checking detected and corrected errors. Go to
"Performing the checkout procedure" on page 177.