Note: When replacing a component, perform system verification for the component. See
"Using the diagnostics program" on page 181.
2. If you cannot perform AIX concurrent online diagnostics, continue to Step 006 .
Step 006
Perform the following steps:
1. Use the management-module Web interface to make sure that the device from which you load
the stand-alone diagnostics is set as the first device in the blade server boot sequence.
2. Turn off the system unit power and wait 45 seconds before proceeding.
3. Turn on the blade server and establish an SOL session.
4. Check for the following responses:
a. Progress codes are recorded in the management-module event log.
b. Record any messages or diagnostic information that might be in the log.
5. Load the stand-alone diagnostics. Go to "Starting stand-alone diagnostics from a CD" on page
179 or "Starting stand-alone diagnostics from a NIM server" on page 180.
6. If you have replaced the failing component, perform system verification for the component.
See "Using the diagnostics program" on page 181
This ends the AIX procedure.
Step 007
Perform the following steps:
1. Use the management-module Web interface to make sure that the device from which you load
the stand-alone diagnostics is set as the first device in the blade server boot sequence.
2. Turn off the blade server and wait 45 seconds before proceeding.
3. Turn on the blade server and establish an SOL session.
4. Check for the following responses:
a. Progress codes are recorded in the management-module event log.
b. Record any messages or diagnostic information that might be in the log.
Continue with step 008 .
Step 008
Load the stand-alone diagnostics. Go to "Starting stand-alone diagnostics from a CD" on page
179 or "Starting stand-alone diagnostics from a NIM server" on page 180.
Can you load the stand-alone diagnostics?
No
Go to "Solving undetermined problems" on page 223.
Yes
Select the resources to be tested and record any SRNs; then go to "Service request
numbers (SRNs)" on page 142.
This ends the Linux procedure.