IBM PS703 Service Manual page 212

7891-73x;7891-74x
Hide thumbs Also See for PS703:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 3, "Parts listing, type 7891," on page 225 to determine which components are CRUs and which
components are FRUs.
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Isolation
Symptom
Procedure Code
FSPSP29
The system has
detected that all I/O
bridges are missing
from the system
configuration.
A problem has been
FSPSP30
encountered
accessing the
management card or
the VPD data found
on the management
card has been
corrupted.
This error occurred
before VPD
collection was
completed, so no
location codes have
been created.
FSPSP31
The service processor
has detected that one
or more of the
required fields in the
system VPD has not
initialized.
FSPSP32
A problem with the
enclosure has been
found.
The problem is one
of the following
problems:
v The enclosure
VPD cannot be
found.
v The enclosure
serial number is
not programmed.
v The enclosure
feature code is not
programmed.
200
Power Systems: Problem Determination and Service Guide for the IBM PS703 (7891-73X) and PS704 (7891-74X)
Action
Replace the system board and chassis assembly, as described in
"Replacing the FRU system-board and chassis assembly" on page 264.
1. Replace the management card, as described in "Removing the tier 2
management card" on page 262 and "Installing the tier 2 management
card" on page 263.
2. After replacing the card and installing the blade server in the chassis
unit and before rebooting the blade server or performing other
operations, ensure that the initialization of the management card VPD
occurs by waiting for the management module to discover the blade
server. Otherwise, the system might fail to IPL.
3. If the problem persists, replace the system board and chassis assembly,
as described in "Replacing the FRU system-board and chassis
assembly" on page 264.
1. When the system reaches the SMS, set the system VPD values that are
required, which automatically resets the service processor.
2. Power on the blade server, as described in "Turning on the blade
server" on page 7.
Record the reason code, which is the last four digits of the first word from
the SRC. Perform one of the following procedures based upon the value
of the reason code:
v Reason code A46F
1. Verify that the operating system is running. If it is running, perform
an in-band firmware update.
2. If the problem persists, replace the system board and chassis
assembly, as described in "Replacing the FRU system-board and
chassis assembly" on page 264.
3. If the problem persists, call IBM Support.
v Reason code A460
1. Set the enclosure serial number using SMS, which automatically
resets the service processor.
2. If the problem persists, call IBM Support.
v Reason code A45F
1. Set the enclosure feature code using SMS, which automatically
resets the service processor.
2. If the problem persists, call IBM Support.
If you do not see your reason code listed, call IBM Support.