IBM PS703 Service Manual page 158

7891-73x;7891-74x
Hide thumbs Also See for PS703:
Table of Contents

Advertisement

Table 27. 101-711 through FFC-725 SRNs (continued)
SRN
FFC
2506-9042
-
2506-9050
-
2506-9051
-
2506-9052
-
2506-9054
-
2506-9060
-
2506-9061
-
2506-9062
-
2506-9063
-
2506-9073
-
2506-9074
-
2506-9075
-
2506-9076
-
2506-9081
-
2506-9082
-
2506-9090
-
2506-9091
-
2506-9092
-
2506-FF3D
2506
2506-FFF3
-
2506-FFF4
722
2506-FFF6
722
2506-FFFA
722
2506-FFFE
-
252B-101
252B
146
Power Systems: Problem Determination and Service Guide for the IBM PS703 (7891-73X) and PS704 (7891-74X)
Description and Action
Background Disk Array parity checking detected and corrected errors on specified disk.
Go to "Performing the checkout procedure" on page 177.
Required cache data can not be located for one or more disks. Go to "Performing the
checkout procedure" on page 177.
Cache data exists for one or more missing/failed disks. Go to "Performing the
checkout procedure" on page 177.
Cache data exists for one or more modified disks. Go to "Performing the checkout
procedure" on page 177.
RAID controller resources not available due to previous problems. Go to "Performing
the checkout procedure" on page 177.
One or more disk pairs are missing from a RAID-10 Disk Array. Go to "Performing the
checkout procedure" on page 177.
One or more disks are missing from a RAID-0 Disk Array. Go to "Performing the
checkout procedure" on page 177.
One or more disks are missing from a RAID-0 Disk Array. Go to "Performing the
checkout procedure" on page 177.
Maximum number of functional Disk Arrays has been exceeded. Go to "Performing the
checkout procedure" on page 177.
Multiple controllers connected in an invalid configuration. Go to "Performing the
checkout procedure" on page 177.
Multiple controllers not capable of similar functions or controlling same set of devices.
Go to "Performing the checkout procedure" on page 177.
Incomplete multipath connection between controller and remote controller. Go to
"Performing the checkout procedure" on page 177.
Missing remote controller. Go to "Performing the checkout procedure" on page 177.
Controller detected device error during internal media recovery. Go to "Performing the
checkout procedure" on page 177.
Controller detected device error during internal media recovery. Go to "Performing the
checkout procedure" on page 177.
Disk has been modified after last known status. Go to "Performing the checkout
procedure" on page 177.
Incorrect disk configuration change has been detected. Go to "Performing the checkout
procedure" on page 177.
Disk requires Format before use. Format the disk and retry the operation.
Temporary controller failure. Retry the operation.
Disk media format bad. Reformat the disk and retry the operation.
Device problem. Perform diagnostics on the device and retry the operation.
Device detected recoverable error. Retry the operation.
Temporary device bus error. Retry the operation.
Temporary device bus error. Retry the operation.
Adapter configuration error.
1. Check the BladeCenter management-module event log. If an error was recorded by
the system, see "POST progress codes (checkpoints)" on page 97.
2. Replace any parts reported by the diagnostic program.
3. Replace the system-board

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ps704

Table of Contents