6.4.4 Analog Torque Input Scaling
The analog voltage between T_REF and GND controls the motor torque command. Using with
parameter P1-41 can adjust the torque control ramp and its range.
Torque command
Relevant parameters:
P1 - 41▲
TCM
Default: 100
Applicable Control Mode: ALL
Unit: %
Range: 0 ~ 1000
Settings:
In Torque mode, this parameter is used to set the output torque at maximum input voltage (10V)
of analog torque command.
In Position and Speed mode, this parameter is used to set output torque at maximum input
voltage (10V) of analog torque limit