Special Function - Delta Electronics ASDA-A Series User Manual

Advanced ac servo drive for general purpose applications
Hide thumbs Also See for ASDA-A Series:
Table of Contents

Advertisement

Call 1(800)985-6929 for Sales
P2 - 65
GBIT
Default: 0
Applicable Control Mode: Pr, Pt, S
Unit: N/A
Range: 0 ~ 3
Settings:
Bit15 Bit14 Bit13 Bit12 Bit11 Bit10 Bit9 Bit8 Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
Bit1
Bit0: DI SPD0/SPD1 speed command trigger mode
Bit1: DI TCM0/TCM1 torque command trigger mode
When the servo drive is rising-edge triggered, the internal commands work as follows:
Bit4
Fast DI (digital input) function. When this function is activated, the function of P2-17(DI8) will
become invalid and change to Fast DI (digital input) function. When Bit3 ~ Bit4 are all set to 0,
this fast DI (digital input) function is disabled.
Bit2: Fast DI contact type
Bit3 ~ Bit4: Fast DI function definition
Bit4
0
0
1
Please note that Bit3 and Bit4 cannot be activated simultaneously.
Revision April 2009
Call 1(800)985-6929 for Sales

Special Function

Bit0
0: by level
1: by rising edge
0: by level
1: by rising edge
Bit3
Bit2
0: normal open or rising edge trigger
1: normal close or falling edge trigger
Bit3
0
Disable fast DI function
1
Fast position latch for DI8 :
When fast position latch function is enabled, the users can get latch
position from LED display by setting P0-02=15 (latch pulses) or
setting P0-02=16 (latch revolutions). The users also can get the
position through the communication by setting P0-04 ~ P0-08.
0
Fast DI INHIBIT for DI8
Response time of the normal DI is 0.4 ~ 0.6ms
Response time of this fast DI is 0.0 ~ 0.1ms
deltaacdrives.com
Chapter 7 Servo Parameters|ASDA-A&A+ Series
A: Execute internal command 1
B: Execute internal command 2
C: Execute internal command 3
D: Execute internal command 3
Function
deltaacdrives.com
sales@deltaacdrives.com
Communication Addr.: 0241H
Related Section: N/A
sales@deltaacdrives.com