Delta Electronics ASDA-A Series User Manual page 269

Advanced ac servo drive for general purpose applications
Hide thumbs Also See for ASDA-A Series:
Table of Contents

Advertisement

Call 1(800)985-6929 for Sales
Chapter 8 MODBUS Communications| ASDA-A&A+ Series
11-bit character frame (For 8-bit character)
8N2
Start
bit
8E1
Start
bit
8O1
Start
bit
Communication Protocol:
ASCII Mode:
STX
ADR
CMD
DATA(n-1)
.......
DATA(0)
LRC
End 1
End 0
RTU Mode:
STX
ADR
CMD
DATA(n-1)
.......
DATA(0)
CRC
End 1
8-10
Call 1(800)985-6929 for Sales
deltaacdrives.com
0
1
2
3
8-data bits
11-bits character frame
0
1
3
2
8-data bits
11-bits character frame
0
1
2
3
8-data bits
11-bits character frame
Start character': ' (3AH)
Communication address: 1-byte consists of 2 ASCII codes
Command code: 1-byte consists of 2 ASCII codes
Contents of data: n word = n x 2-byte consists of n x 4 ASCII codes, n≤12
Command code: 1-byte consists of 2 ASCII codes
End code 1: (0DH)(CR)
End code 0: (0AH)(LF)
A silent interval of more than 10ms
Communication address: 1-byte
Command code: 1-byte
Contents of data: n word = n x 2-byte, n≤12
Command code: 1-byte
A silent interval of more than 10ms
deltaacdrives.com
4
5
6
7
4
5
6
7
4
5
6
7
sales@deltaacdrives.com
Stop
Stop
bit
bit
Even
Stop
parity
bit
Odd
Stop
parity
bit
Revision April 2009
sales@deltaacdrives.com

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents