4.4.4 Force Output Control Operation

For testing, the digital outputs can be forced to be activated (ON) or inactivated (OFF) by using
parameter P4-06. Follow the setting method in Figure 4.6 to enter into Force Output Control operation
(OP xx) mode ("xx" indicates the parameter range from 00 to 1F). Pressing UP or DOWN arrow key can
change "xx" value from 00 to 1F (hexadecimal format) and force digital outputs DO1 to DO5 to be
activated (ON) or inactivated (OFF). The DO function and status is determined by P2-18 to P2-22. This
function is enabled only when Servo Off (the servo drive is disabled).
Figure 4.6
4-10
Call 1(800)985-6929 for Sales
deltaacdrives.com
Force DO to be ON
Force DO1 to be ON
Force DO2 to be ON
Force DO3 to be ON
Force DO4 to be ON
Force DO5 to be ON