Igbt Ntc Calibration - Delta Electronics ASDA-A Series User Manual

Advanced ac servo drive for general purpose applications
Hide thumbs Also See for ASDA-A Series:
Table of Contents

Advertisement

Call 1(800)985-6929 for Sales
Chapter 7 Servo Parameters|ASDA-A&A+ Series
P4 - 19
TIGB
Default: Factory setting
Applicable Control Mode: ALL
Unit: N/A
Range: 1~7
Settings:
Manual Adjustment Operation:
Set parameter P2-08 to 22 and then change this parameter. This is an auxiliary adjusting
function, although this parameter allows the users can execute manual adjustment, we still do
not recommend users to change the default setting manually.
Auto Adjustment Operation:
Set parameter P2-08 to 20 first and then set parameter P4-10 to 6. When executing this auto
adjustment, please ensure to cool the servo drive to 25
1) When P2-08 is set to 10, users cannot reset this parameter.
P4 - 20
DOF1
Default: Factory setting
Applicable Control Mode: ALL
Unit: mV
Range: -800~800
Settings:
When P2-08 is set to 10, users cannot reset this parameter.
P4 - 21
DOF2
Default: Factory setting
Applicable Control Mode: ALL
Unit: mV
Range: -800~800
Settings:
When P2-08 is set to 10, users cannot reset this parameter.
7-88
Call 1(800)985-6929 for Sales
deltaacdrives.com

IGBT NTC Calibration

NOTE
Analog Monitor Output Drift Adjustment (CH1)
Analog Monitor Output Drift Adjustment (CH2)
deltaacdrives.com
Communication Addr.: 0413H
Related Section: N/A
o
C.
Communication Addr.: 0414H
Related Section:
Section 6.4.4
Communication Addr.: 0415H
Related Section: N/A
Section 6.4.4
sales@deltaacdrives.com
Revision April 2009
sales@deltaacdrives.com