Chapter 7 Servo Parameters|ASDA-A&A+ Series
P2 - 17
DI8
Default: 21
Applicable Control Mode: ALL
Unit: N/A
Range: 0 ~ 147
Settings: See P2-10 for explanation.
P2 - 18
DO1
Default: 101
Applicable Control Mode: ALL
Unit: N/A
Range: 0 ~ 112
Settings:
This parameter is used to determine the function and status of DO1.
Please re-start the servo drive after parameters have been changed.
P2 - 19
DO2
Default: 103
Applicable Control Mode: ALL
Unit: N/A
Range: 0 ~ 112
Settings: See P2-18 for explanation.
P2 - 20
DO3
Default: 109
Applicable Control Mode: ALL
Unit: N/A
Range: 0 ~ 112
Settings: See P2-18 for explanation.
7-56
Call 1(800)985-6929 for Sales
deltaacdrives.com
Digital Input Terminal 8 (DI8)
Digital Output Terminal 1 (DO1)
A
B
not used
Digital Output Terminal 2 (DO2)
Digital Output Terminal 3 (DO3)
deltaacdrives.com
Communication Addr.: 0211H
Related Section:
Table 7.A
Communication Addr.: 0212H
Related Section:
Table 7.B
• A: DO Function Settings: For the setting value of
P2- 18 ~ P2-22, please refer to Table 7.A.
• B: DO Enabled Status Settings:
0: Normally closed (contact b)
1: Normally open (contact a)
Communication Addr.: 0213H
Related Section:
Table 7.B
Communication Addr.: 0214H
Related Section:
Table 7.B