Di Diagnosis Operation; Do Diagnosis Operation - Delta Electronics ASDA-A Series User Manual

Advanced ac servo drive for general purpose applications
Hide thumbs Also See for ASDA-A Series:
Table of Contents

Advertisement

Call 1(800)985-6929 for Sales

4.4.5 DI Diagnosis Operation

Following the setting method in Figure 4.7 can perform DI diagnosis operation (parameter P4-07, Input
Status or Force Input Control). According to the ON and OFF status of the digital inputs DI1 to DI8, the
corresponding status will display on the servo drive LED display. When the segment lit and display on
the screen, it means that the corresponding digital input signal is ON. (Please also refer to Figure 4.7)
Figure 4.7

4.4.6 DO Diagnosis Operation

Following the setting method in Figure 4.8 can perform DO diagnosis operation (parameter P4-09,
Output Status Display). According to the ON and OFF status of the digital outputs DO1 to DO5, the
corresponding status will display on the servo drive LED display. When the segment lit and display on
the screen, it means that the corresponding digital input signal is ON. (Please also refer to Figure 4.8)
Figure 4.8
Revision April 2009
Call 1(800)985-6929 for Sales
deltaacdrives.com
Chapter 4 Display and Operation|ASDA-A&A+ Series
DI10 DI9 DI8 DI7 DI6 DI5 DI4 DI3 DI2 DI1
Light:
OFF
OFF
ON
DO10 DO9 DO8
Light:
OFF
OFF
OFF OFF OFF
deltaacdrives.com
SET
ON
ON
ON
ON
ON
SET
DO5DO4 DO3 DO2 DO1
ON
ON
ON
sales@deltaacdrives.com
ON
ON
ON
ON
4-11
sales@deltaacdrives.com

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents