 The system generates log files automatically from the time the
machine power is turned on until it is turned off.
 When reaching maximum capacity (engine log: 512KB, debug log:
8MB), new log files will be generated automatically.
 The directory where the log files are saved to corresponds to the
machine serial number.
 File names consist of date & time; year/month/date/hour/min/sec
Slide 76
No additional notes
Capturing the Debug Logs
Engine Log and Debug Log - 5
without a file extension as shown below.
» Engine logs: root/[s/n]/unf_yyyymmddHHMMSS
» Debug logs: root/ [s/n]/dbg_yyyymmddHHMMSS