Slide 172
The machine has three NVRAMs. There are two on the controller board, and one
on the BCU.
Replacement
Controller Board (1)
There are two NVRAMs [A] [B] on the
controller board. The two NVRAMs
are one set.
When replacing the controller board,
remove the NVRAMs from the old
controller board.
Then install them at the same
positions on the new controller
board. If this is not done, SC195-00
occurs.
NVRAM 2M-1 is inserted at socket
[C] labeled FRAM-1. Make sure
that the circular notch [E] on the
NVRAM is pointing in the direction
of arrow [G] on the board.
NVRAM 2M-1 is inserted at socket
[D]. Make sure that the circular
notch [F] on the NVRAM is pointing
in the direction of the arrow [H] on
the board.
If the NVRAMs are installed
incorrectly, this could cause both
the board and the NVRAMs to
short out and cause permanent
damage.
172
BR-C1 Training