 These SP codes must be set after ADF replacement.
 4-712-001: CIS GB Adj Value: R
 4-713-001: CIS GB Adj Value: G
 4-714-001: CIS GB Adj Value: B
 A data sheet is provided with a new ADF unit.
 The sheet lists the SP codes for the CIS and the values that
must be entered for each SP.
 After setting all the SP codes, print an SMC report so you
can have a record of the new values in case you need to
replace the NVRAM at a later time.
 After you have done that, check for skew and make sure
the platen is installed correctly, as explained in the
replacement procedure.
Slide 200
No additional notes
Replacement and Adjustment
After Replacing the ADF