9. After cleaning and lubrication, close the front doors.
10. Wait for about 5 minutes. You will see a message on the screen
when you are ready to continue.
11. Open the front doors, install the PTR unit and then install the
drum cleaning unit. Then lower and lock the levers.
12. Reset the counters for replaced parts
13. Close the front doors.
 This ends the procedure.
 Do the above procedure, even if you are replacing only the
ITB cleaning unit and not the belt.
 This is because the blades of the new ITB cleaning unit
could easily scratch the surface of the belt, or cause
unnecessary wear, causing the belt to deteriorate.
Slide 387
No additional notes
Replacement and Adjustment
Re-installing the ITB Cleaning Unit - 2
SP 7-622-021 for ITB cleaning unit
SP 7-622-022 for ITB cleaning blade
SP 7-622-023 for ITB lubricant brush roller
SP 7-622-024 for ITB lubricant bar
SP 7-622-025 for ITB lubricant blade