1. After re-assembling the machine, open the left and front doors.
2. Turn the machine on.
3. Enter the operator adjust mode.
4. Enter the SP mode, open SP7622-018 to set the counter to zero,
and then leave the SP mode.
5. Close the left and right front doors.
6. Process control executes automatically.
7. After process control executes, the operation panel will display
"Ready".
If process control fails, you will see "Fail" appear on the operation
Do the procedure recommended to resolve the problem that
You must then execute SP3011-002 to execute process control
This completes the procedure.
Enter the SP mode, and then do SP3012-001 to confirm that
process control executed successfully.
Slide 249
No additional notes
Replacement and Adjustment
After Installing a New Drum - 5
panel, and then the machine will issue an SC code.
triggered the SC code.
manually because it will not execute again automatically.