1. When installing developer in a new development unit: Add
the contents of the small (145g) bag of developer that
comes with the new unit through the open port of the new
development unit.
2. Make sure that both front doors are open, then turn the
machine on.
3. When installing developer in a new development unit:
Enter the SP mode, open SP3029-001 and make sure that it
is set to the default value (400).
 This step prevents incorrect detection by the development
4. Shake the new bottle from side to side 3 times, and then
shake up and down about 3 times to loosen the developer.
5. Do not remove the seal from the new bottle until after it has
been connected to the front of the machine.
6. Attach the developer bottle to the machine.
7. Remove the seal.