Ricoh BR-C1a Basic Service Training page 70

Table of Contents

Advertisement

Controller and Operation Panel - 2
 Insert the SD card into the slot on the side of the operation
panel.
 Set the start date of the log with SP5-857-101
 e.g.: March 28, 2013: input 20130328 (yyyymmdd)
 Set the date three days earlier than the occurrence of the
problems.
 Set the end date of the log with SP5-857-102
 e.g.: March 30, 2013: input 20130330 (yyyymmdd)
 Execute SP5-857-103 to write the debug log to the SD card.
 The approximate time it takes to transfer the log is as
follows. Transfer time may be affected by the type or format
of the SD card.
» Controller log (GW debug log): 2 - 20 minutes
» Operation panel log: 2 - 20 minutes
Slide 70
 See the 'Capturing the Debug Logs' section in the service manual for details of
the procedures.
Capturing the Debug Logs
70
BR-C1 Training