Slide 408
No additional notes
Toner Paths
1. Upper horizontal path. Used
toner from the drum cleaning
unit.
2. PTR cleaning unit path. Used
toner from the PTR cleaning
unit.
3. Vertical Path. Used toner from
the ITB cleaning unit; upper
path and PTR path also empty
into this duct.
4. Lower horizontal path.
Collection point for all the
sources of used toner and
paper dust.
If one of the coils becomes
jammed, the used toner lock
sensor will stop the used toner
transport motor, and the
machine will issue SC488.
408