 Lubricant is applied to the service parts at the factory, so
they require no further lubrication (setting powder or
yellow toner) before they are installed.
 However, you must execute SP2310-001 to force
lubrication and cleaning after they have been installed.
 The cleaning blade can replaced separately. It requires no
lubrication, but SP2310-001 still must be done.
 The lubricant brush roller, lubricant bar, and lubricant
blade are always replaced together, not separately, but
SP2310-001 must be done after they are replaced.
 When the ITB unit is replaced as a unit, SP2310-001 still
must be done.
Slide 388
See the following table for a summary.
Part
Cleaning blade *1
Lubricant brush roller
*3
Lubricant bar *3
Lubricant blade *2 *3
*1: Setting power (zinc stearate) applied before shipping.
*2: Yellow toner applied before shipping
*3: Always replaced together as a set.
Replacement and Adjustment
Notes about Lubrication
When Replaced
Individually
SP2310-001
---
388
When ITB Unit
Replaced as a
Unit
SP2310-001