iVu Plus TG and Color Gen2 Image Sensors
TriggerACK

15.9 Command Channel Command Status Register

The command status register will confirm receipt of a command by reflecting the exact command ID received, regardless of
whether the command was valid or not.

15.10 Diagnostic Guide

iVu devices provide several methods to help diagnose communication issues when using Ethernet communications.

15.10.1 Ethernet Diagnostics

To verify Ethernet connectivity, follow these steps:
1. Verify that all of the cables are connected and properly seated.
2. Examine the Ethernet I/O LED located on the top of the iVu, between the Pass/Fail and System Status LEDs. The
light should be either on or blinking.
3. Go to System > Logs > System Log.
4. Verify that the log entry indicates that the Ethernet link is up:
206
RPI
0
1
Trigger
Ready
Set
Trigger = 1
Verify :
Ready = 1
TriggerACK
= 0
Figure 273. Trigger Timing Diagram
www.bannerengineering.com - Tel: + 1 888 373 6767
Trigger
X
X + Y X + Y + Z
Set
Trigger = 0
Verify :
TriggerACK
= '1 '
Ready = 1
Read Results
TriggerACK
= 0