Configuring A Mask - Banner iVu Plus TG Series Instruction Manual

Ivu plus tg and color gen2 image sensors
Table of Contents

Advertisement

iVu Plus TG and Color Gen2 Image Sensors
Icon
After all of the sensors are configured as required for the application, the inspection Pass/Fail criteria is determined by
considering the results of the individual sensors. An inspection is considered as PASS if all sensors in the inspection pass. If
any sensor fails, the inspection is marked as FAIL.

13.11 Configuring a Mask

A mask created for a sensor does not apply to any other sensors in the inspection. The mask ROI type can be rectangular,
elliptical, or circular. Use up to ten masks per sensor.
1. Select the desired ROI. When selected, the ROI has resize and rotation icons in the corners.
2. Click [Sensor Name] to open the sensor parameters menu.
3. Select ROI and Mask.
4. Select the Enable Mask checkbox.
5. Click
to return to the Home screen.
6. Re-select the ROI from step 1.
7. Click
to insert the mask. The mask displays in blue with a diagonal line pattern in the region.
96
Function
Move the selected sensor down in the execution order
Edit the name of the selected sensor
Delete the selected sensor
Figure 144. Parameters Menu
Figure 145. ROI and Mask Screen