iVu Plus TG and Color Gen2 Image Sensors
Set the Pass Count parameter.
The Minimum Pass Count is the minimum number of parts, labels, or features expected to fall within the
specified criteria. The Maximum Pass Count is the maximum number expected to fall within the specified
criteria. These settings are used to determine the pass or fail result of the inspection.
In the Demo, set the Minimum Pass Count and Maximum Pass Count to 9. If the count is more than 9 or less
than 9, the sensor will fail.
Adjust the Tolerance.
Adjust the tolerance for the color the sensor is looking for. Adjustments are made individually for hue,
saturation, and intensity.
In the Demo example, the Tolerance is set to 10.
6. Test a complete range of good and bad samples to make sure that the sensor accepts good parts and rejects bad
parts.
7. To complete the Color Area application setup, adjust the trigger setting as appropriate for the application.
Note: Remote Teach does not work with the Color Area sensor.

13.10 Configuring Multiple Sensors in the Inspection

Main > Inspection > Sensors > Add Sensor
Some applications require more than one sensor. New sensors can be added after an inspection has been created. Input
parameters for each sensor can be configured individually.
94
Note: Start with the Maximum Pass Count—the Minimum will not allow it to be more than
the maximum.
www.bannerengineering.com - Tel: + 1 888 373 6767
Figure 138. Pass Count Screen
Figure 139. Tolerance Screen