Inputs To Ivu (Outputs From Plc); Outputs From Ivu (Inputs To Plc) - Banner iVu Plus TG Series Instruction Manual

Ivu plus tg and color gen2 image sensors
Table of Contents

Advertisement

iVu Plus TG and Color Gen2 Image Sensors

15.6.2 Inputs to iVu (Outputs from PLC)

The registers below are used by the PLC to push values to the iVu device. MSG (message) commands are used to write
(N14) to the iVu.
Table 49: PCCC PLC Output Registers (iVu Inputs, N14 Table)
WORD #
WORD NAME
0
Input Bits Register (see
1-2
Product Change Number
3-49
reserved
50
Command ID
51
Command Parameter Int16
52-53
Command Parameter Int 32
54-55
Command Parameter
56-57
Command Parameter String Length
58-107
Command Parameter String
reserved
108
for Barcode models only
109-120
211-239
reserved

15.6.3 Outputs from iVu (Inputs to PLC)

The registers below are used to send output values from the iVu device to the PLC. MSG (message) commands are used to
read (N7) from the iVu.
164
To Address = IP address of the iVu
Figure 211. MultiHop tab: IP address of the iVu is entered here
Input and Output Flags
www.bannerengineering.com - Tel: + 1 888 373 6767
DATA TYPE
(p. 169))
16-bit integer
32-bit integer
32-bit integer
16-bit integer
16-bit integer
32-bit integer
Float
32-bit integer
100-Byte Array
16-bit integer
16-bit integer