When either Sensor Pass or Sensor Fail is selected, additional settings become available as shown in
Click the yellow arrow to access the Select Sensor screen.
On the Select Sensor screen, the check box allows sensor position to be part of the logic that activates the output. One or
more sensor positions can be added. The right column shows the sensor name(s) and their respective position from the
current inspection for reference.
The drop-drop list has two settings:
All Selected—All checked sensor positions must meet the setting criteria (Pass/Fail) to activate the output
Any Selected—Any checked sensor position that meets the setting criteria (Pass/Fail) will activate the output
When a selected sensor position is missing on the current inspection, the missing sensor(s) will not be part of the logic to
activate the output. For example, when only 2 sensors are included on the current inspection and the Output > Select
Sensor(s) has Sensor #1, Sensor #2, and Sensor #3 checked, only Sensor #1 and Sensor #2 are used to determine the
output state. This is because Sensor #3 is not defined by the current inspection.

11.7 Display Settings

Main Menu > System > Display Settings
Use the Display Settings menu to set the Fail Hold Time, LCD Timeout, and to perform a Touch Calibration for the
touchscreen display. Enable display optimization from the Advanced menu.
Figure 85. Output # Screen
Figure 86. Output # Screen with Additional Settings
Figure 87. Select Sensor(s) Screen
www.bannerengineering.com - Tel: + 1 888 373 6767
iVu Plus TG and Color Gen2 Image Sensors
Figure 86
(p. 71).