Sort Menu - Banner iVu Plus TG Series Instruction Manual

Ivu plus tg and color gen2 image sensors
Table of Contents

Advertisement

iVu Plus TG and Color Gen2 Image Sensors
Pass Count
Main Menu > Inspection > Sensors > [Sensor Type] > Pass Count
The Minimum Pass Count is the minimum number of parts, labels, or features expected to fall within the specified criteria.
The Maximum Pass Count is the maximum number expected to fall within the specified criteria. These settings are used to
determine the pass or fail result of the inspection.
Edit Pattern
Main Menu > Inspection > Sensors > Match > Edit Pattern
The Edit Pattern feature allows pixels in a taught pattern to be removed, or restored after being removed. Click
remove pixels from the pattern. Click
Advanced
Main Menu > Inspection > Sensors > Match > Advanced
Use the Advanced menu to enable Search ROI and Track with Motion. These options apply to all Match sensors in the
current inspection.
Search ROI—Sets a custom region within the field of view to search for the pattern. When Search ROI is enabled,
both Teach and Search ROIs display. The Teach ROI is blue. The Search ROI is green or red, depending on whether
the sensor passes or fails.
Track with Motion—Moves the ROIs with Motion. Motion must be enabled under Inspection > Properties.
Timeout
Main Menu > Inspection > Sensors > [Sensor Type] > Timeout
When the sensor type is set as Match or Sort, use the Timeout screen to adjust the maximum time the inspection is allowed
to execute. A timeout error is reported in the case the inspection runs out of time. If this value is set too high, the sensor can
miss triggers while trying to detect a bad pattern.

9.1.4 Sort Menu

Main Menu > Inspection > Sensors > Sort
Use a Sort sensor to recognize and sort up to ten different patterns within the same inspection. Teach each reference
pattern during setup. Store reference patterns in one of ten pattern memory locations. A reference pattern might include
alphanumeric characters, logos, or any other shapes. The pass criteria can be set for any or all of the patterns.
Example application include:
Identify and sort parts on a production line
Ensure that several different parts are present in a package
The Sort sensor is a single sensor inspection. It must be the only sensor in the inspection. Add a Sort sensor from Main
Menu > Inspection > Stored Inspections > Add New.
Use the Sort sensor parameters to manage stored patterns and to configure Sort sensor inspection parameters:
Saved Patterns
Percent Match
Rotation Range
Pass Criteria
Timeout
42
Draw to restore removed pixels to the pattern.
Figure 45. Sort Menu
www.bannerengineering.com - Tel: + 1 888 373 6767
Eraser to

Hide quick links: