Configuring A Match Sensor - Banner iVu Plus TG Series Instruction Manual

Ivu plus tg and color gen2 image sensors
Table of Contents

Advertisement

iVu Plus TG and Color Gen2 Image Sensors
The Minimum Pass Count is the minimum number of parts, labels, or features expected to fall within the
specified criteria. The Maximum Pass Count is the maximum number expected to fall within the specified
criteria. These settings are used to determine the pass or fail result of the inspection.
Use the brackets to set a tolerance for the pass/fail.
Now the inspection for the blemish sensor is sensitive enough to find blemishes under the logo and fail the
inspection.
6. Test a complete range of good and bad samples to make sure that the sensor accepts good parts and rejects bad
parts.
7. To complete the Blemish application setup, adjust the trigger setting as appropriate for the application.
Note: Remote Teach does not work with the Blemish sensor.

13.4 Configuring a Match Sensor

Teach the sensor a good reference part.
1. Begin the setup with a good part.
2. Center the part to be tested in the Field of View (FOV).
3. Adjust the Region of Interest (ROI) so that it surrounds the feature of interest. In the Demo example, the feature of
interest is the Banner logo.The ROI type can be rectangular, elliptical, or circular.
84
Figure 110. Pass Count Screen
Figure 111. Blemishes Found During the Inspection
Figure 112. Adjust the ROI
www.bannerengineering.com - Tel: + 1 888 373 6767