Set the Pass Count parameter as appropriate.
The Minimum Pass Count is the minimum number of parts, labels, or features expected to fall within the
specified criteria. The Maximum Pass Count is the maximum number expected to fall within the specified
criteria. These settings are used to determine the pass or fail result of the inspection.
In the Demo, both the Minimum Pass Count and Maximum Pass Count are set 1. If the count is more than 1
or less than 1, the sensor will fail.
8. If Search ROI is enabled, adjust the Search ROI as desired to set a custom region within the field of view to search
for the pattern.
9. Test a complete range of good and bad samples to make sure that the sensor accepts good parts and rejects bad
parts.
10. To complete the Match application setup, adjust the trigger setting as appropriate for the application.
Note: When running a Match inspection, the sensor looks for any possible patterns to match anywhere
within the Field of View.

13.4.1 Remote Teach

The Remote Teach function is a method of remotely updating inspection parameters while the iVu is running. Remote Teach
is only available when the iVu is configured as a Match sensor. The sequence of events for executing a Remote Teach are:
1. With the device Ready (see
2. The iVu recognizes that the Remote Teach line has been pulsed and waits for the next valid trigger.
3. At the next valid trigger, Ready goes inactive (the Green Ready LED shuts OFF), and the iVu acquires a new image.
4. The iVu learns the new pattern and performs the analysis.

13.5 Configuring a Sort Sensor

When running a Sort inspection, the sensor looks for any possible patterns to match anywhere within the field of view.
Note: Rotations Range and Percent Match work together. The higher the Percent Match,
the lower the Rotation Range to pass. In the previous example a 99% match is too high
for any rotation. In the next graphic the Percent Match has been lowered to 92% which
still fails a missing letter.
Installation Instructions
www.bannerengineering.com - Tel: + 1 888 373 6767
Figure 119. Rotation Range Screen
Figure 120. Pass Count Screen
(p. 17)), pulse the Remote Teach line.