Vision Manager Error Codes - Banner iVu Plus TG Series Instruction Manual

Ivu plus tg and color gen2 image sensors
Table of Contents

Advertisement

Note: If the device name is longer than eight characters, only the first eight characters are used in
the folder name. If the device has no name, the folder name is the first eight characters of the
device serial number.
4. Disconnect the USB flash drive from the iVu device.
5. Connect the USB flash drive to a Windows PC that has Vision Manager installed.
6. Copy the device configuration file from USB flash drive to desired location on the PC.
For example, when debugging inspections for an iVu Color device, the image files can be located at: C:\Users
\Public\Documents\Banner Vision Manager\iVu Series\iVu Color.
7. Make sure the bitmap (.bmp) files to be used for debugging are located in "InspLog" subfolder at that location.
For example, C:\Users\Public\Documents\Banner Vision Manager\iVu Series\iVu Color\InspLog. To avoid confusion,
remove the bitmap (.bmp) or Inspection Log files (.log) files in the InspLog folder so that those files will not be used
for debugging. The iVu Emulator automatically uses all .bmp and .log files sequentially according to filename.
8. Start Vision Manager and click Emulators.
9. For the desired Emulator, click
saved. For example, [USB:]\BANNER\myName.
10. Click
to connect to the Emulator.
The Emulator runs with the configuration on the USB flash drive using .bmp files in the InspLog folder. Inspections
occur depending the Trigger Mode settings.
11. Make the desired adjustments to the inspection or inspections.
12. On the Home screen, click
All configuration changes are automatically saved to the CONFIG.CFG file on the PC.
13. Copy the modified device configuration file from the PC to the USB flash drive ([USB:]\BANNER\myName).
14. Disconnect the USB flash drive from the PC.
15. Connect the USB flash drive to the iVu device.
16. Restore the configuration to the iVu device.
a) Go to Main Menu > System > Sensor Configuration > Load Configuration.
b) Select the configuration to restore.
c) Click Load to start the restore device configuration.
d) Restart the device when the restore is complete.

16.3 Vision Manager Error Codes

Error Code
Description
10000
The sensor's feature set is too old
to work with this version of Vision
Manager.
10001
The sensor's feature set is too new
to work with this version of Vision
Manager.
10005
The sensor was not found at the
specified IP address. Network
PING results indicate no device
present at the specified IP address.
and select the path on USB flash drive to which the device configuration was
to disconnect the Emulator.
Recommended Solution
Update the sensor firmware to a version compatible with this
application
Install an older version of this application
Install an newer version of this application
Downgrade the sensor firmware to a version compatible with
this application
Verify the sensor is energized
Verify the sensor communication cable is connected
Verify all inline network equipment is energized, properly
configured and connected
Verify all required network equipment cables are connected
Verify the network adaptor is properly configured
Verify the sensor IP address is valid
Verify the sensor subnet is valid
www.bannerengineering.com - Tel: + 1 888 373 6767