10. Test a complete range of good and bad samples to make sure that the sensor accepts good parts and rejects bad
parts.
11. To complete the Sort application setup, adjust the trigger setting as appropriate for the application.

13.6 Configuring Motion

Main Menu > Inspection > Motion
The Motion menu is available when Motion is enabled under the Inspection Properties menu.
Enable Motion when the part being inspected is expected to move or rotate. Motion settings for Edge involve selecting the
number of edges to locate, adjusting sensitivity, and selecting whether rotation is enabled. Motion settings for Match
involve selecting the Teach ROI type, adjusting the percent match and rotation range, editing the taught pattern, and setting
a timeout. These settings are available on the Inspection Menu after Motion is set to Edge or Match.
Motion is not available for Sort sensors.
Figure 124. Motion Menu when Motion is set to Edge
Note: For a Match sensor, enable Track with Motion at Main Menu > Inspection > Sensors > Match >
Advanced.

13.6.1 Number of Edges

Main Menu > Inspection > Motion > Number of Edges
Number of Edges is available when Motion is set to Edge.
On the Number of Edges screen, use the option buttons to select One Edge or Two Edges. If One Edge is selected, motion
is tracked in one direction (by default, horizontally). If Two Edges is selected, motion can be tracked horizontally and
vertically.

13.6.2 Sensitivity

Main Menu > Inspection > Motion > Sensitivity
Sensitivity is available when Motion is set to Edge.
Use Sensitivity to fine-tune how sensitive the sensor is to finding a reference edge.
The sensitivity value helps account for light variations that might affect how well the sensor detects edges on inspected
parts. The sensitivity scale is from 0 to 100, where 0 means least sensitive and 100 means most sensitive. If set near 0, the
sensor only finds very sharp edges with strong contrast. If set near 100, the sensor finds very dim or blurry edges, and may
be unstable due to noise within the image.

13.6.3 Rotation

Main Menu > Inspection > Motion > Rotation
Rotation is available when Motion is set to Edge.
Rotation can be enabled or disabled. Select Enabled if the part can be expected to rotate during the inspection.
www.bannerengineering.com - Tel: + 1 888 373 6767
iVu Plus TG and Color Gen2 Image Sensors
Figure 125. Motion Menu when Motion is set to Match