Inspection Id; Motion; Stored Inspections Menu; Select - Banner iVu Plus TG Series Instruction Manual

Ivu plus tg and color gen2 image sensors
Table of Contents

Advertisement

iVu Plus TG and Color Gen2 Image Sensors
The Inspection Name screen displays the name of the current inspection. Edit the name of the inspection on this screen.

9.3.2 Inspection ID

Main Menu > Inspection > Properties > Inspection ID
Click the dropdown arrow to view a list of IDs assigned to all inspections on this device. Choose any unused ID to change
the ID of this inspection. The original ID is marked as Unused.
Swap the ID of this inspection with another inspection by selecting that inspection on the list.

9.3.3 Motion

Main Menu > Inspection > Properties > Motion
Enable Motion when the part being inspected is expected to move or rotate. Motion finds and marks the position of a
reference point and positions related sensors consistently over a feature of interest. Select Edge or Match as the Motion
reference point.

9.4 Stored Inspections Menu

Main Menu > Inspection > Stored Inspections
Use the Stored Inspections menu to manage stored inspections. Managing stored inspections includes adding or deleting
inspections, and specifying which inspection is the startup inspection.
Figure 52. Stored Inspections Menu
From the Stored Inspections menu, click Select, Add New, Startup, Delete, or Set Name/ID.

9.4.1 Select

Main Menu > Inspection > Stored Inspections > Select
Use the Select screen to select a new running inspection. Click the name of the inspection to start, and click Start Running.

9.4.2 Add New

Main Menu > Inspection > Stored Inspections > Add New
Use Add New to add a new inspection. The iVu can store up to 30 inspections. When you add a new inspection, it begins
running. Set the Sensor Type and the inspection name when adding a new inspection.