Image Export - Banner iVu Plus TG Series Instruction Manual

Ivu plus tg and color gen2 image sensors
Table of Contents

Advertisement

iVu Plus TG and Color Gen2 Image Sensors
Data Export Advanced
Main Menu > System > Communications > Data Export > Advanced
During the Data and Image export operation, the iVu output channels might become full. This can occur if the iVu is
producing export data (frames) faster than the data can be exported from the device or faster than the client is reading the
channel export data (due to bandwidth limitations).
The Advanced setting affects how the iVu behaves in this situation.
Select Hold READY to ensure that all frames are transmitted. In this case, the READY signal remains inactive (iVu is busy)
until the new frame has been added to the channel for transmission. Triggers might be missed during this time.
Select Do not hold READY to cause the iVu to discard the new frame if the channel is full and thus activate the READY
signal immediately after the current inspection is complete. In this case, the discarded frames are not transmitted.
Note: This setting affects both the Data Export Channel and Image Export Channel.

11.5.6 Image Export

Main Menu > System > Communications > Image Export
When the Image Export Channel is enabled, the iVu transmits the acquired image on every trigger. The image is transmitted
as a bitmap (.bmp) file. This operation is only available over Ethernet I/O.
Connection
Main Menu > Communications > Image Export > Connection
Use the Connection screen to enable or disable the Image Export.
Image Type
Main Menu > System > Image Export > Image Type
On the Image Type screen, choose between .jpg or .bmp format for the exporting image file.
68
Figure 79. Output Format Screen
Figure 80. Advanced Screen