1.5 Periodic Replacement Parts

Replace periodic replacement parts based on the life counter value checked during TRIM servicing.
Periodic Replacement Parts
FUSING UNIT
Retard Roll(KIT HOLDER ASSY RETARD
CST)
Transfer Roll(BTR)
KIT DADF PICK UP MODULE(DADF)
Use Condition:
The print volume of the replacement life is based on continuous printing using A4 landscape sheets.
Use the replacement life only as a guide because it varies depending on conditions such as print
content, paper size, paper type, environment, and frequency of powering on/off.
The FUSING UNIT has no CRUM, and therefore the counter for it needs to be reset manually. To
reset the counter, refer to Chapter 6 "6.9.2 Display and Initialization of the Life Counter(Life)", and
initialize the life counter value of Fusing PV/Fusing Heat time.
The Retard Roll(KIT HOLDER ASSY RETARD CST) has no counter, and therefore it needs to be
replaced together with the FUSING UNIT.
The Transfer Roll(BTR) has no CRUM, and therefore the counter for it needs to be reset manually.
To reset the counter, refer to Chapter 6 "6.9.2 Display and Initialization of the Life Counter(Life)" and
initialize the life counter values of Trans Unit PV.
The KIT DADF PICK UP MODULE (ROLLER ASSY DADF+SEPARATION PAD) for DADF has no
counter, and therefore it needs to be replaced together with the FUSING UNIT.
Table 1-2
Part No.
110V
604K77738
220V
604K77748
604K78360
604K77060
604K77110
1-11
Chapter 1 Service Call Procedure
1.5 Periodic Replacement Parts
Replace-
CRUM
ment Interval
100KPV
No
100KPV
No
100KPV
No
100KPV
No
35K FEED
No
Counter
Remarks
Reset
Yes
CRU
Yes
CRU
No
CRU
Yes
CRU
No
CRU