IQ-12
Bead-Carry-Out (BCO)
Step
Setting the altitude.
Set the Altitude.
1
- To set the altitude, use [Adjust Altitude] on the [Maintenance]
of [Admin Menu].
Is the image printed correctly?
Checking after resetting the Drum Cartridge.
2
Reseat the Drum Cartridge.
Is the image printed correctly?
Checking after resetting the HVPS.
3
Reseat the HVPS.
Is the image printed correctly?
Checking after replacing the Drum Cartridge.
4
Replace the Drum Cartridge.
Is the image printed correctly?
Chapter 3 Image Quality Troubleshooting
Possible causative parts
- Drum Cartridge [XERO ASSY] (PL8.1.1)
- HVPS (PL18.2.5)
Check and Action
3-27
3.2 Image Quality Troubleshooting
Yes
End of work.
End of work.
End of work.
End of work.
No
Go to step 2.
Go to step 3.
Go to step 4.
Replace the
HVPS. (REP
18.3)