5.5 Performing the installation

With KITAS hexagonal seal

5 - 24
The following description describes the procedure for using the
KITAS 2171 in the integrated, screw-in version. In the case of the
other methods of installation, the procedure is identical.
1
Fig. 5 - 11: Sealing the KITAS 2171 at the transmission (with KITAS hex-
agonal seal)
1. If required, remove the KITAS sensor cable (3) from the
KITAS 2171.
2. Slide the KITAS seal (1) onto the KITAS 2171 until it locks into
place.
3. Then clamp the bracket at the KITAS seal (2) using seal
crimpers, thereby signing the seal.
4. Connect the KITAS sensor cable (3) to the KITAS 2171 via the
bayonet-type connection.
Observe the instructions on sealing, see chapter 5.2.4 "Lead sealing
the DTCO 1381 components", page 5-10.
© Siemens VDO Automotive AG
Installation
2
3