4.2 The flow of data and memory behaviour
Event
Data error motion and
speed
Security breach
Overspeeding
Interruption of power
supply
4 - 10
Saving regulations
•
The longest event on each of the 10
most recent days of appearance
•
The 5 longest events of the last 365
days
•
The 10 most recent events by type of
event
•
The most severe instance of the 10
most recent days of appearance (the
event with the highest average speed)
•
The 5 most severe events of the last
365 days
•
The first event after the most recent cal-
ibration
•
The longest event on each of the 10
most recent days of appearance
•
The 5 longest events of the last 365
days
© Siemens VDO Automotive AG
Recorded data
•
Begin – date and time
•
End – date and time
•
The type, number, and issuing member
state of an inserted card at the
beginning and/or end of the event.
•
Number of the same types of events on
this day.
•
Type of event
•
Begin – date and time
•
End – date and time (if relevant)
•
The type, number, and issuing member
state of an inserted card at the
beginning and/or end of the event.
•
Begin – date and time
•
End – date and time
•
Measured highest speed
•
Measured arithmetic average speed
•
The driver's card type, number, and
issuing member state (if applicable)
•
Number of the same types of events on
this day.
•
Overspeeding control – date and time
•
First instance of overspeeding after the
most recent control – date and time
•
Number of instances of overspeeding
after the most recent control
•
Begin – date and time
•
End – date and time
•
The type, number, and issuing member
state of an inserted card at the
beginning and/or end of the event.
•
Number of the same types of events on
this day.
Note
This data can be recorded only after re-
establishing the power supply, whereby the
accuracy here can be one minute.
Data handling
Edition 07/2007