Events and faults
DTCO 1381 display
Picto.
AP
Error text
1)
These warning messages will be displayed repetitively every hour until the cause is withdrawn.
2)
These warning messages are not saved in the date memory during calibration mode.
Edition 07/2007
MC
Error code
Meaning, cause and measures
4000000700
Printer fault.
Possible causes
Measures
– Interrupt continuous voltage (perform restart).
– After a long printout, the print head temperature is too
If the error message continues to appear despite these
measures and multiple acknowledgements, replace the
DTCO 1381.
4000001030
Display fault (sometimes no display).
Possible causes
Measures
If the error message appears repetitively, replace the
DTCO 1381.
---
A communication fault has appeared while downloading
card or memory data.
Measures
– Repeat download process.
– Check connection cable to download station and plug
– Check download interface on the DTCO 1381.
– Check download station.
Replace any defective components.
8000002508
Internal sensor fault; the KITAS 2171 motion sensor
announces an internal fault after a self-test.
Measures
– Check KITAS 2171.
Replace KITAS 2171 if necessary.
Technical Description DTCO 1381
13.4 Messages and troubleshooting measures
The printer's supply voltage lies outside of the specified
range or has failed.
The temperature of the print head is outside the spec-
ified range or monitoring supplies values which are not
plausible.
Fault on the temperature sensor of the print head.
high; wait to cool.
Data transfer to display controller faulty.
Display defective.
(poor connection, loose contact, pin assignment).
1)
2)
1)
2)
2)
2)
13 - 25