13.4 Messages and troubleshooting measures
DTCO 1381 display
Picto.
Error text
13 - 16
MC
Error code
Meaning, cause and measures
00000005B3
A tachograph card cannot be ejected; the request is rejected.
Possible causes
Measures
– Check whether the DTCO 1381 detects "drive"; if so, stop the
– Check whether data is currently being downloaded; if so,
– Check whether the ignition is on, turn ignition on if necessary
– Repeat process.
If the error message continues to appear despite these measures,
replace the DTCO 1381.
00000005B3
While reading-in a tachograph card, an inconsistency is found in
the links within the date data.
Measures
– Check tachograph card.
– Analyze data structure.
00000005B3
The inserted card cannot be read or written to.
Possible causes
Measures
– Check to make sure the tachograph card is valid.
– Make sure the tachograph card is correctly inserted and insert
– Check tachograph card.
– Check if another tachograph card is read correctly.
© Siemens VDO Automotive AG
Vehicle is moving
Download of data from the requested tachograph card is in
progress
Ignition is off (only ADR variant)
The tachograph card is being read or written on
The tachograph card is requested within the same minute
during which the tachograph card is correctly read in (after
insertion or after restart during activation).
vehicle and repeat the process.
repeat the process after the download is finished.
(only ADR variant).
Card inserted incorrectly
Card is defective
properly if needed.