Creating And Sealing Installation Plate - Siemens VDO DTCO 1381 Technical Description

Digital tachograph
Table of Contents

Advertisement

First calibration

10.5.7 Creating and sealing installation plate

Edition 07/2007
After the first calibration, the installation plate must be attached on,
in, or directly next to the recording equipment where it will be easily
visible.
1. The following information must be transferred to the instal-
lation plate:
• Calibration date
• Effective wheel circumference (l-value, max. of four digits)
• Characteristic coefficient (w-value, max. of five digits)
• Recording equipment constant (k-value, five digits)
• Vehicle identification number (max. of 17 digits)
• Device number (max. 10 digits)
• Tire size (max. 15 digits)
• Name and address or company logo*.
2. Attach the installation plate on, in, or directly next to the
recording equipment where it will be easily visible.
3. Secure the installation plate with sealing foil.
The installation plate must be protected with a sealing foil, unless it
is installed in a way that it cannot be withdrawn without destroying
the information it provides.
The installation plate must be replaced after every intervention into
the system.
* The name and address or company logo of the workshop or the
manufacturer may be printed on the sealing foil.