Data handling
Faults (errors)
Fault
Card faults
Recording equipment fault •
Calibration data
Edition 07/2007
The DTCO 1381 saves faults (errors) with a resolution of one second.
The following data will be saved for every fault (error):
Saving regulations
•
The 10 most recent driver card faults
The 10 most recent faults of each fault
type
•
The first fault after the most recent cali-
bration
The DTCO 1381 registers and saves the following calibration data in
its data memory:
•
Programmed calibration parameters at the time point of the acti-
vation
•
The first calibration after activation
•
The first calibration in the current vehicle (depending on the
chassis number)
•
The 5 most recent calibrations
If several calibrations are performed on one calendar day, only the
last calibration will be saved.
•
Date and purpose of the calibration
– Activation (1)
– Initial installation (2)
– Installation (3)
– Regularly inspection (4)
•
Name and address of the workshop
•
Number of the workshop card, issuing member state, validity
Technical Description DTCO 1381
4.2 The flow of data and memory behaviour
Recorded data
•
Begin – date and time
•
End – date and time
•
A card's type, number, and issuing
member state.
•
Type of fault
•
Begin – date and time
•
End – date and time
•
The type, number, and issuing member
state of an inserted card at the
beginning and/or end of the fault.
4 - 11