1.2 Digital Tachograph DTCO 1381
1 - 8
(4)
Download and calibration interface
The download and calibration interface is located under the
cover.
Download interface: When a company card, control card, or
workshop card is inserted, data can be read out from the
memory and the inserted tachograph cards.
Calibration interface: The DTCO 1381 is calibrated or tested
through the calibration interface.
(5)
Driver 2 keypad
Activity button for driver 2
Ejection button for card slot 2
(6)
Device sealing
To secure against unauthorized opening of the housing.
(7)
Card slot 2 (with mechanical lock)
The driver who will not steer the vehicle inserts his driver card
into slot 2 (crew operation).
(8)
Unlock button
Button to unlock the printer drawer, like when inserting a new
roll of paper.
(9)
Printer
Integrated printer for outputting data from the internal
memory or the inserted tachograph cards.
Model plate
The model plate is visible after opening the printer drawer and
removing the paper roll:
a
b
c
d
e
f
(a) Manufacturer
(b) Device type
(c) Serial number
(d) Year or date of manufacture
(e) Test/approval mark
e1-84 (EC recording equipment), e1-034091 (EMC)
(f) External item number
(g) Release version
(h) Part of the drawing reference number
(10) Menu buttons
/
Select desired function,
acknowledge function or confirm actions,
leave menu one step at a time or cancel the function.
© Siemens VDO Automotive AG
Product and system overview
Edition 07/2007
h
g

Advertisement