Siemens VDO DTCO 1381 Technical Description page 255

Digital tachograph
Table of Contents

Advertisement

Events and faults
DTCO 1381 display
Picto.
AP
Error text
1)
These warning messages will be displayed repetitively every hour until the cause is withdrawn.
2)
These warning messages are not saved in the date memory during calibration mode.
Edition 07/2007
MC
Error code
Meaning, cause and measures
8000001177
Fault or interruption in the communication with an external
display instrument (reset monitoring).
Measures
– Check the function / configuration of the DTCO 1381,
– Check the connection cable between the DTCO 1381 and
– Check functionality of the display unit, e.g. send reset-
– Check functionality of the DTCO 1381.
– Check calibration data of the DTCO 1381 (variant / con-
Replace any defective components if necessary.
Comment
Monitoring of this fault depends on the configuration of the
DTCO 1381:
The DTCO 1381 may not be the cause of the error.
4000000400
Fault in the card mechanics.
4000000500
Possible causes
Measures
– Re-insert tachograph card.
– Request the tachograph card again.
– Interrupt continuous voltage (perform restart).
If the error message continues to appear despite these
measures, replace the DTCO 1381.
Comment
Any inserted tachograph card is ejected. This error is reset
when a tachograph card has been inserted correctly.
Technical Description DTCO 1381
13.4 Messages and troubleshooting measures
correct if necessary.
the display instrument:
a) Pin assignment
b) Connection
c) Specifications
message
figuration).
Monitoring of this fault can be activated or deactivated
(CANEVCfg).
The fault can be suppressed for a certain period after
ignition "on" (ErrorManagementInitialisationInhibit).
Card lock not closed
General error in the card mechanics
1)
1)
2)
13 - 23

Advertisement

Table of Contents
loading

Table of Contents