General Instructions; Chapter 7 Preprogramming; Delivery Condition Of The Dtco 1381 - Siemens VDO DTCO 1381 Technical Description

Digital tachograph
Table of Contents

Advertisement

Preprogramming
7.1

General instructions

7.1.1 Delivery condition of the DTCO 1381

Edition 07/2007
Installation of the DTCO 1381 is divided into the following steps:
1. Installation
Mechanical and electrical installation of the DTCO 1381 compo-
nents into the vehicle.
2. Preprogramming
Preprogramming of all known or operationally necessary and
legally required parameters.
3. Installation and functional test
Test and demonstration that the entire system complies with
the permissible error limits concerning distance and speed,
defined by CR (EEC) 3821/85, annex I B.
4. Activation
Activation of the DTCO 1381 to be an EC recording equipment
(with the first insertion of the workshop card).
5. First calibration
First calibration of the EC recording equipment. Part of the first
calibration is, to enter the vehicle registration number.
The DTCO is delivered in the non-activated condition; the following
default parameters are set at the factory:
Vehicle identification number
Vehicle registration number
Characteristic coefficient (w-value) [p/km]
Recording equipment constant (k-value)
Effective wheel circumference [mm]
Tire size
Legally permitted maximum speed [km/h]
2)
UTC time
Odometer reading [km]
1)
Calibration date
1)
The DTCO 1381 sets this data automatically.
2)
Actual UTC time; the UTC time is set for the first time at the time of
production of the DTCO 1381.
Technical Description DTCO 1381

7.1 General instructions

?????????????????
?????????????
8000
1)
[p/km] 8000
0000
???????????????
0
hh:mm
0000000
00.00.00
7 - 3