14.5 Memory behaviour during events or faults

14.5 Memory behaviour during events or faults
1
2
Coding of data record purpose
14 - 30
For each established event or fault, the DTCO 1381 will register and
save the data according to the specified rules.
(1)
Data record purpose
(2)
Number of similar events on this day
The data record purpose (1) indicates why the event or fault was
recorded. Events of the same type appearing several times on this
day are displayed at pos. (2).
The following overview shows the events and faults arranged
according to error type (cause) and the assignment of the data
record purpose:
Picto
Cause
Card conflict
Driving without valid card
Insertion while driving
Card not closed
Overspeeding
Power interruption
Sensor fault
Security breach
Time overlap
Card invalid
Card fault
Internal fault
Internal fault
Display fault
Faults during downloading
Sensor fault
1)
This event will be saved only on the driver card
2)
The DTCO 1381 will not save this event
© Siemens VDO Automotive AG
1)
2)
Appendix
Data record purpose
0
1, 2, 7
3
0
4, 5, 6
1, 2, 7
1, 2, 7
0
0
0, 6
0, 6
0, 6
0, 6
0, 6
Edition 07/2007