Pos. / block
Data block specification / explanation
Handwritten information
21
Information about the cardholder of the recorded profile
22
• Last name of driver
• First name of driver
• Card identification
Remark
Missing information about the cardholder means: no driver card inserted in card slot 1.
• Beginning of the profile recording with date and time
• End of the profile recording with date and time
Remark
New profiles are created:
– by inserting / withdrawing a tachograph card into / from card slot 1
– by a day change
– by a correction of the UTC time
– by a voltage interruption
Recording of speed profile
23
• List of the defined speed ranges and period in this range
• Range: 0 <= v < 1 = Vehicle motionless
The speed profile is divided into 16 zones. During installation, the individual ranges can
be adjusted individually.
Recording of rpm profile
24
• List of the defined motor rpm ranges and period in this range
• Range: 0 <= n < 1 = Motor off
• Range: 3281 <= n < x = unlimited
The rpm profile is divided into 16 zones. During installation, the individual ranges can be
adjusted individually.
Edition 07/2007
= Location of control
= Signature of the controller
= Start time
= End time
= Signature of the driver
Technical Description DTCO 1381
14.4 Explanation of printout examples
14 - 29