Bus-PIP9: For use by authorized service providers.
You will need to perform Bus-PIP9 on an SPD migrated tower. Go to "Bus-PIPs for migrated towers" for
more information.
Bus-PIP10: For use by authorized service providers.
You will need to perform Bus-PIP10 on an SPD migrated tower. Go to "Bus-PIPs for migrated towers" for
more information.
Bus-PIP11: For use by authorized service providers.
You will need to perform Bus-PIP11 on an SPD migrated tower. Go to "Bus-PIPs for migrated towers" for
more information.
Bus-PIPs for migrated towers: For use by authorized service providers.
The failure is in a migrated tower.
SPD migrated towers are connected with a high-speed link and have bus numbers 0004 through 0017
(hexadecimal) or 4 through 23 (decimal).
Use Hardware Service Manager (HSM), the System Configuration Listing, or visually inspect the SPD
migrated I/O tower to determine the feature code of the tower. Record the tower's feature code number.
You will need the Migrated Expansion Tower Problem Analysis, Repair and Parts manual on the V5R1
Supplemental Manuals web site
Procedures section in the Migrated Expansion Tower Problem Analysis, Repair and Parts manual on the
V5R1 Supplemental Manuals web site
sent there to perform using the migrated tower feature code that you recorded.
Bus PIP CNSL01: For use by authorized service providers.
Use this procedure to exchange the I/O processor for the system or partition console.
1. Does the system have multiple partitions?
v No: Go to step 8 (See page 78).
v Yes: Is the problem on a secondary partition?
– Yes: Continue with the next step.
– No: Go to step 8 (See page 78).
2. Can the customer power off the partition at this time?
v Yes: Power down the partition from the Primary partition's Work with partition status display. Then,
continue with the next step.
v No: The IOP controlling the partition's console may be controlling other critical resources. The
partition must be powered off to exchange this IOP. Perform this procedure when the customer is
able to power down the partition from the Primary partition's Work with partition status display. Then,
continue with the next step.
3. Determine the logical address and the frame ID of the console IOP using the following steps:
a. In SST/DST, select Work with System Partitions —> Display partition information —> Display
allocated I/O resources.
b. Page down until you find the console IOP for the partition that you are working with.
c. Select Display logical address.
d. Record the bus, card and board logical address for the console's IOP.
to continue. Go to Bus PIP Entry Point in the Bus Problem Isolation
. Follow the instructions to get to the Bus-PIP that you were
Analyze hardware problems
77